Figure 29: System health voltage thresholds

Using the Avaya Remote Supervisor Adapter

Viewing system health summary

NOTE:

You must check the Voltage box under the Alerts section for a voltage alert to be sent to the configured alert recipients.

When you click on a specific value associated with a component, the following window opens.

Figure 29: System health voltage thresholds

The reported voltages for the designated system components are measured in the following ranges:

Warning Reset: If the voltage returns to a value below the warning reset value, the RSA assumes that the voltage has returned to normal and does not generate any further alerts.

Warning: If the voltage reaches or exceeds the value specified for a warning, an alert is generated.

Soft Shutdown: When the voltage reaches or exceeds the value specified for a soft shutdown a second voltage alert is sent and the RSA begins the shutdown of the S8500 Media Server. The shutdown will be an orderly O/S shutdown. The S8500 Media Server turns itself off when the shutdown completes.

Hard Shutdown: When the voltage reaches or exceeds the value specified for a hard shutdown, the S8500 Media Server immediately shuts down. The RSA sends out an alarm to the configured alert recipients.

Fan speed

The RSA monitors the fan running speed of the S8500 Media Server (see Figure 30, System health fan speed, on page 57). The speed is express in a percentage of the maximum fan speed. A fan alert is generated if the fan speed drops in an unacceptable level or the fan stops.