STEP ONE

The first step is to determine the parameters needed to configure the Fast Ethernet interface (ETH0). The parameters in the Network Protocol Menu (IP) are shown in Figure 4.2. Fill in the blanks for your application in the right-most column. These parameters will be entered into the PR4000 later, after all parameters have been determined. Each parameter in this menu is explained in more detail in chapter 5 of the Installation Guide.

Menu CONFIG=>INTERFACE=>FAST ETHERNET=>NETWORK PROTOCOL=>IP

Parameter

Example

 

Your Application

Active or Inactive

Active enables IP communication (IPX and Transparent

 

 

Bridge are not used in this example).

 

Interface Unnumbered

Numbered

 

 

Primary IP Address

100.130.130.1

 

 

Subnet Mask

255.255.255.0

 

 

Secondary IP Address

0.0.0.0 for none.

 

 

Enable Dynamic Local

No

 

 

IP Address

 

 

 

IP MTU

Use the preset value, 1500.

This determines whether

 

 

or not a given IP datagram is fragmented.

 

NAT

Global, because NAT is not being used in this example.

 

ICMP Port

Inactive

 

 

Incoming Rule List

None, filters and traffic control are not included in this

 

 

example.

 

 

Outgoing Rule List

None, filters and traffic control are not included in this

 

Name

example.

 

 

Proxy ARP

Inactive

 

 

IP Bridge

Inactive

 

 

FIGURE 4.2 ETHERNET NETWORK PROTOCOL MENU PARAMETERS

STEP TWO

No more parameters are necessary for the Ethernet interface. The next step is the configuration of the E1 or T1

Chapter 4 - Step-By-Step Instructions for Common Applications