Controller Menu

CONFIG=>CONTROLLER=>T1/E1

 

 

 

Parameter

 

Description

Frame Mode

 

T1: ESF (Extended Super Frame, the most common) and D4 are the options.

 

 

E1: CRC4 (the most common) and Non-CRC4are the options.

Line Code

 

T1: B8ZS (Bipolar 8 Zero Substitution, the most common) and AMI (Alternate Mark

 

 

Inversion). E1: HDB3 (High-Density Bipolar) and AMI.

Signaling Mode

 

None for channelized lines without signaling (see chapter 7), CCS for ISDN-PRI and CAS

 

 

for analog, modem-based remote access (usually used with telephone networks that do not

 

 

support ISDN).

Clock Mode

 

Selects the clock mode: Master or Slave.

Line Build Out

 

Applies only to T1. Sets the attenuation on the TX line. The T1 service provider should

 

 

supply this parameter.

Receiver

 

Short haul is usually used. Long haul is necessary if attenuation prevents reception of

Sensitivity

 

data, usually when the router is installed more than 2000 feet from the cable termination.

Companding

 

Defines the compression mode to be used. Depends on the telephone exchange and the

Mode

 

E1/T1 provider should supply this parameter. A-lawis usually used for E1 lines and u-law

 

 

is usually used for T1 lines.

Signaling Type

 

Applies when Signaling Mode is CAS. Selects the signaling type. This should be supplied

 

 

by the service provider. The options are R2-Digital, ITU-T, and R2-Analog.

Tone Signaling

 

Applies when Signaling Mode is CAS. Will depend on what is expected by the line provider.

 

 

DTMF is the most common tone signaling for T1 and MFR2 Compelled is the most

 

 

common for E1.

Country

 

Applies when Signaling Mode is CAS. Determines country-dependent signaling

Signaling

 

parameters.

Switch Type

 

Applies when Signaling Mode is CCS. Selects the signaling protocol. This should be

 

 

supplied by the service provider.