Rate Limiting

Set up each port’s bandwidth rate and frame limitation type.

„Ingress Limit Frame type: Select the frame type to filter. There are

four options: All, Broadcast/Multicast/Flooded Unicast, Broadcast/Multicast and Broadcast only.

„Egress Limit: The egress rate limit is ALL.

Rate Limiting interface

„All the ports support port ingress and egress rate control. For example, assume port 1 is 10Mbps, users can set its effective egress rate to 1Mbps, and ingress rate is 500Kbps. The switch performs the ingress rate limiting using a packet counter to meet the specified rate

¾Ingress: Enter the port effective ingress rate(The default value is ‘0’)

¾Egress: Enter the port effective egress rate(The default value is ‘0’)

„Click Apply

66

Manual Documentation Number: EIR608-xSFP_0708m

 

 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104www.bb-elec.com

 

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445www.bb-europe.com

Page 74
Image 74
B&B Electronics EIR608-xSFP manual Rate Limiting