Manual Documentation Number: EIR618-2SFP-T_5107m 43
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
monitor function fastEthernet 2
switch(config-if)#no monitor
802.1x Commands Set
Commands Level Description Example
8021x enable G
Use the 802.1x global
configuration
command to enable
802.1x protocols.
switch(config)# 8021x enable
8021x system radiusip
[IP address]
G Use the 802.1x system
radius IP global
configuration
command to change
the radius server IP.
switch(config)# 8021x system
radiusip 192.168.1.1
8021x system serverport
[port ID]
G Use the 802.1x system
server port global
configuration
command to change
the radius server port
switch(config)# 8021x system
serverport 1815
8021x system
accountport
[port ID]
G Use the 802.1x system
account port global
configuration
command to change
the accounting port
switch(config)# 8021x system
accountport 1816
8021x system sharekey
[ID]
G Use the 802.1x system
share key global
configuration
command to change
the shared key value.
switch(config)# 8021x system
sharekey 123456
8021x system nasid
[words]
G Use the 802.1x system
nasid global
configuration
command to change
switch(config)# 8021x system
nasid test1