User’s Manual
Model
Page
B+K Precision Corp
B&K Precision
Model User’s Manual
2.0 Installation and setup
5.0 Mode descriptions
1.0 Introduction
3.0 Operating controls and keys
Warranty information
6.0 Remote operation
7.0 Arbitrary waveform system
8.0 DC Operation Option
Figure 1.0-1:The BK Precision model
1.0 Introduction
1 BK Precision 4071 User Manual Rev.2.2
1.1 Description
1.2 Feature summary
Modes
1. SYNC out connector
2.0 Installation and setup
2. SIG Out connector
3. External Modulation In connector
4. External Trigger/Gating/FSK/BPSK input
result by exceeding this input voltage limit
7. RS232 Interface connector
6. External Arb Sync In / Out connector
8. Line in connector
3.1 Mode key
3.0 Operating controls and keys
3.2 Field arrow keys
3.3 Recall / Store key
3.6 Numeric keys 0 to 9, - and
3.5 Trigger key
3.7 é, ê, è, ç keys
3.8 Clear key
3.10 One Touch Mode Keys
3.9 MHz/dBm, KHz/Vp-p/Sec, Hz/mVp-p/mSkeys
4.4 Operating mode selection
4.0 Operating guide
4.1 Changing frequency
4.2 Changing level
4.5.1 Modifying an existing value
4.5 Changing values
4.5.2Entering a new value
5.0 Mode descriptions
5.1 Basic Sinewave CW Mode
Sinewave Mode
Sinewave Mode Parameters
5.2 Internal AM Mode
Internal AM Mode Parameters
Int AM: 1,000 Hz
Percent Mod: 100%
5.3 External AM Mode
External AM Mode Parameters
External AM
Input gain:
5.4 Internal FM Mode
Internal FM Mode Parameters
Int FM: 1,000 Hz
Pk dev: 10,000 Hz
5.5 External FM Mode
External FM Mode Parameters
External FM
1. Peak Frequency Deviation
5.6 Internal PM Mode
Internal PM Mode Parameters
2. Peak Phase Deviation
Int PM: 1,000 Hz
5.7 External PM Mode
External PM Mode Parameters
1. Peak Phase Deviation
External PM
5.8 Sweep Mode
Sweep Mode Parameters
St: 1,000,000.00 Hz
Stp: 20,000,000.00 Hz
SYNC Out Connector
5. Up / Down sweep
6. Sweep time
7. Level
5.9 Internal FSK Mode
Internal FSK Mode Parameters
Int FSK: 1,000 Hz
Mark: 1,000,000.00 Hz
5.10 External FSK Mode
External FSK Mode Parameters
Ext FSK
1. Mark Frequency
5.11Burst Mode Introduction
Burst Mode
1. Continuous / Triggered Mode
4. Burst Off Time delay
5.12 Internal SSB Mode
Internal SSB Mode Parameters
Int SSB: 1,000 Hz
Upper Sideband
5.13 External SSB Mode
External SSB Mode Parameters
External SSB
1. Upper/Lower Sideband selections
5.16 DTMF Generation Mode
Delay
DTMF Generation Mode Parameters
DTMF generation: #
3. DTMF Delay
2. DTMF Duration
4. Level
Offset
5.17 DTMF Detection Mode
DTMF Detection Mode Parameters
DTMF detection on Ext Mod input 1 2 3 # A
1. DTMF detected digits
5.18 Power & Voltage Measurement Mode
Power & Voltage Measurement Mode Parameters
1. Power Level
4. External Modulation In Connector
5.19 Arbitrary Mode
5.20 Remote Mode
5.21 Other mode
Select Mode
5.22 Internal BPSK Mode
Internal BPSK Mode Parameters
1Int BPSK: 1,000 Hz
10.0 dBm
5.23 External BPSK Mode
External BPSK Mode Parameters
External BPSK
1. Carrier Frequency
5.24 Dualtone Generation Mode
Dualtone Generation Mode Parameters
3. Phase Offset
10,000 Hz F2
Dualtone Examples
Ext Gating Input
5.25 Data Modulation Mode
Using the Data Modulation Mode
Data Modulation Mode Parameters
Data
Downloading Modulation Message Data
Example Message
Offset
Ext Trigger Input
Triggering the Transmission
Saving the Message
5.26 Voltage Controlled Oscillator VCO Mode
VCO Mode Parameters
Start
0 Hz
6.2 Connecting
6.0 Remote Operation
6.1 Introduction
6.3 Checking your connection with Hyper Terminal
6.4 Remote Control Operation
6.5 Remote Control Programming Rules
6.6 Remote Control Commands
Z Y X C
E1,0 - Enable, Disable LCD echo to terminal
V - Report hardware and software versions
Stp: 31,500,000.00 Hz
Linear | Trig | Up | Time: 10,000 mS
10.0dBm
0 Hz
6.7 Remote Control Examples
Example
Example
Example
7.0Arbitrary Waveform Mode
7.1Quick Start Guide
9 pin - 9-pincable
9 pin - 25 pin cable adapter
7.2 Introduction to the Arbitrary Waveform System
Introduction
7.3 Switching Modes
7.2.2 Feature Summary
Function Generator
Pulse Generator
7.4 Arbitrary Waveform Mode
Arb Mode Int
Phase: 126.35 deg
2. Phase
7.5 Function Generator Mode
2. Continuous/Triggered mode
Function Gen
Wave: Pos Ramp
7.6 Pulse Generator Mode
3. Continuous / Triggered mode
Pulse Gen
Only? N Duty Cycle: 50 %
7.7.1 Using WAVELOAD.EXE
7.7 Downloading arbitrary waveforms
Saving Arbitrary Waveforms
C:>WAVELOAD /COMx /y /baud:z filename.ext
7.7.2 Using your own program
7.8 Data Formats
7.8.1 Floating Point Format
Example
Rules for Floating Point format
Example #2
7.8.2 Time & Value Floating Point Format
Example
7.8.3 Digital Format
Example
Example
7.8.4 Integer Format
Rules for Integer format
Rules for Hexadecimal format
7.8.5 Hexadecimal Format
Example
Rules for Binary format
7.8.6 Binary Format
Example
7.9 Multiple Units Locking
Generator
7.9.1 Introduction to Multiple Arb Locking
Quick Start Guide
More on Phase Offsets
Phase Resolution
Waveform Size Restrictions
Example
ARB.BAS
7.10 Example Arb Program
Program Listing - ARB.BAS
63 BK Precision 4071 User Manual Rev.2.2
F = Floating Point I = Integer
PRINT #1, PointVal
Send Floating point number to
RETURN
Send Integer data to
PRINT #1, a
Send integer value to
RETURN
66 BK Precision 4071 User Manual Rev.2.2
67 BK Precision 4071 User Manual Rev.2.2
68 BK Precision 4071 User Manual Rev.2.2
Wiring Diagram
Specifications
8.0 DC Operation Option
Description
Operating Modes
9.0 4071 Specifications
70 BK Precision 4071 User Manual Rev.2.2
UPDATE
10.0 Software CD
CALIBRATE
REMOTE
Appendix A
Hardware Setup
will cause permanent damage to the
73 BK Precision 4071 User Manual Rev.2.2
74 BK Precision 4071 User Manual Rev.2.2
75 BK Precision 4071 User Manual Rev.2.2
76 BK Precision 4071 User Manual Rev.2.2
Television Remote Control Example
Appendix B
Hardware Setup
Background
78 BK Precision 4071 User Manual Rev.2.2
79 BK Precision 4071 User Manual Rev.2.2
80 BK Precision 4071 User Manual Rev.2.2
Model Number: ______________
Limited Two-YearWarranty
Date Purchased: __________
Service Information
82 BK Precision 4071 User Manual Rev.2.2
PN: 481-419-9-001Printed in the U.S.A
22820 Savi Ranch Pkwy Yorba Linda, CA 92887 USA
2002 B&K Precision Corp