Model
User’s Manual
Page
B&K Precision
B+K Precision Corp
Model User’s Manual
3.0 Operating controls and keys
2.0 Installation and setup
5.0 Mode descriptions
1.0 Introduction
8.0 DC Operation Option
Warranty information
6.0 Remote operation
7.0 Arbitrary waveform system
1.0 Introduction
Figure 1.0-1:The BK Precision model
1 BK Precision 4071 User Manual Rev.2.2
1.1 Description
Modes
1.2 Feature summary
2.0 Installation and setup
1. SYNC out connector
2. SIG Out connector
3. External Modulation In connector
result by exceeding this input voltage limit
4. External Trigger/Gating/FSK/BPSK input
6. External Arb Sync In / Out connector
7. RS232 Interface connector
8. Line in connector
3.3 Recall / Store key
3.1 Mode key
3.0 Operating controls and keys
3.2 Field arrow keys
3.5 Trigger key
3.6 Numeric keys 0 to 9, - and
3.7 é, ê, è, ç keys
3.10 One Touch Mode Keys
3.8 Clear key
3.9 MHz/dBm, KHz/Vp-p/Sec, Hz/mVp-p/mSkeys
4.2 Changing level
4.4 Operating mode selection
4.0 Operating guide
4.1 Changing frequency
4.5 Changing values
4.5.1 Modifying an existing value
4.5.2Entering a new value
Sinewave Mode Parameters
5.0 Mode descriptions
5.1 Basic Sinewave CW Mode
Sinewave Mode
Percent Mod: 100%
5.2 Internal AM Mode
Internal AM Mode Parameters
Int AM: 1,000 Hz
Input gain:
5.3 External AM Mode
External AM Mode Parameters
External AM
Pk dev: 10,000 Hz
5.4 Internal FM Mode
Internal FM Mode Parameters
Int FM: 1,000 Hz
1. Peak Frequency Deviation
5.5 External FM Mode
External FM Mode Parameters
External FM
Int PM: 1,000 Hz
5.6 Internal PM Mode
Internal PM Mode Parameters
2. Peak Phase Deviation
External PM
5.7 External PM Mode
External PM Mode Parameters
1. Peak Phase Deviation
Stp: 20,000,000.00 Hz
5.8 Sweep Mode
Sweep Mode Parameters
St: 1,000,000.00 Hz
7. Level
SYNC Out Connector
5. Up / Down sweep
6. Sweep time
Mark: 1,000,000.00 Hz
5.9 Internal FSK Mode
Internal FSK Mode Parameters
Int FSK: 1,000 Hz
1. Mark Frequency
5.10 External FSK Mode
External FSK Mode Parameters
Ext FSK
4. Burst Off Time delay
5.11Burst Mode Introduction
Burst Mode
1. Continuous / Triggered Mode
Upper Sideband
5.12 Internal SSB Mode
Internal SSB Mode Parameters
Int SSB: 1,000 Hz
1. Upper/Lower Sideband selections
5.13 External SSB Mode
External SSB Mode Parameters
External SSB
DTMF generation: #
5.16 DTMF Generation Mode
Delay
DTMF Generation Mode Parameters
Offset
3. DTMF Delay
2. DTMF Duration
4. Level
1. DTMF detected digits
5.17 DTMF Detection Mode
DTMF Detection Mode Parameters
DTMF detection on Ext Mod input 1 2 3 # A
4. External Modulation In Connector
5.18 Power & Voltage Measurement Mode
Power & Voltage Measurement Mode Parameters
1. Power Level
Select Mode
5.19 Arbitrary Mode
5.20 Remote Mode
5.21 Other mode
10.0 dBm
5.22 Internal BPSK Mode
Internal BPSK Mode Parameters
1Int BPSK: 1,000 Hz
1. Carrier Frequency
5.23 External BPSK Mode
External BPSK Mode Parameters
External BPSK
10,000 Hz F2
5.24 Dualtone Generation Mode
Dualtone Generation Mode Parameters
3. Phase Offset
Ext Gating Input
Dualtone Examples
Data
5.25 Data Modulation Mode
Using the Data Modulation Mode
Data Modulation Mode Parameters
Ext Trigger Input
Downloading Modulation Message Data
Example Message
Offset
Saving the Message
Triggering the Transmission
0 Hz
5.26 Voltage Controlled Oscillator VCO Mode
VCO Mode Parameters
Start
6.3 Checking your connection with Hyper Terminal
6.2 Connecting
6.0 Remote Operation
6.1 Introduction
6.5 Remote Control Programming Rules
6.4 Remote Control Operation
Z Y X C
6.6 Remote Control Commands
V - Report hardware and software versions
E1,0 - Enable, Disable LCD echo to terminal
0 Hz
Stp: 31,500,000.00 Hz
Linear | Trig | Up | Time: 10,000 mS
10.0dBm
Example
6.7 Remote Control Examples
Example
Example
9 pin - 25 pin cable adapter
7.0Arbitrary Waveform Mode
7.1Quick Start Guide
9 pin - 9-pincable
Introduction
7.2 Introduction to the Arbitrary Waveform System
Pulse Generator
7.3 Switching Modes
7.2.2 Feature Summary
Function Generator
2. Phase
7.4 Arbitrary Waveform Mode
Arb Mode Int
Phase: 126.35 deg
Wave: Pos Ramp
7.5 Function Generator Mode
2. Continuous/Triggered mode
Function Gen
Only? N Duty Cycle: 50 %
7.6 Pulse Generator Mode
3. Continuous / Triggered mode
Pulse Gen
C:>WAVELOAD /COMx /y /baud:z filename.ext
7.7.1 Using WAVELOAD.EXE
7.7 Downloading arbitrary waveforms
Saving Arbitrary Waveforms
7.7.2 Using your own program
Rules for Floating Point format
7.8 Data Formats
7.8.1 Floating Point Format
Example
7.8.2 Time & Value Floating Point Format
Example #2
Example
Example
7.8.3 Digital Format
7.8.4 Integer Format
Example
Rules for Integer format
7.8.5 Hexadecimal Format
Rules for Hexadecimal format
Example
7.8.6 Binary Format
Rules for Binary format
Example
Quick Start Guide
7.9 Multiple Units Locking
Generator
7.9.1 Introduction to Multiple Arb Locking
Example
More on Phase Offsets
Phase Resolution
Waveform Size Restrictions
7.10 Example Arb Program
ARB.BAS
Program Listing - ARB.BAS
63 BK Precision 4071 User Manual Rev.2.2
F = Floating Point I = Integer
Send Integer data to
PRINT #1, PointVal
Send Floating point number to
RETURN
66 BK Precision 4071 User Manual Rev.2.2
PRINT #1, a
Send integer value to
RETURN
67 BK Precision 4071 User Manual Rev.2.2
68 BK Precision 4071 User Manual Rev.2.2
Description
Wiring Diagram
Specifications
8.0 DC Operation Option
9.0 4071 Specifications
Operating Modes
70 BK Precision 4071 User Manual Rev.2.2
REMOTE
UPDATE
10.0 Software CD
CALIBRATE
Hardware Setup
Appendix A
will cause permanent damage to the
73 BK Precision 4071 User Manual Rev.2.2
74 BK Precision 4071 User Manual Rev.2.2
75 BK Precision 4071 User Manual Rev.2.2
76 BK Precision 4071 User Manual Rev.2.2
Background
Television Remote Control Example
Appendix B
Hardware Setup
78 BK Precision 4071 User Manual Rev.2.2
79 BK Precision 4071 User Manual Rev.2.2
80 BK Precision 4071 User Manual Rev.2.2
Limited Two-YearWarranty
Model Number: ______________
Date Purchased: __________
82 BK Precision 4071 User Manual Rev.2.2
Service Information
22820 Savi Ranch Pkwy Yorba Linda, CA 92887 USA
PN: 481-419-9-001Printed in the U.S.A
2002 B&K Precision Corp