SRP-270

3-5-2(d) Signal Description

 

 

Function

 

 

Pin No.

Signal name

Direction

 

 

 

 

1

Frame GND

-

 

Frame Ground

 

 

2

SD2

Output

 

Send Data

 

 

3

SD1

Output

 

”H” : SD1 > SD2 , “L” : SD1 < SD2

 

 

4

RD2

Input

 

Receive Data

 

 

5

RD1

Input

 

”H” : RD1 > RD2 (RD1-RD2 ≥ 0.2V)

 

 

 

 

“L” : RD1 < RD2 (RD1-RD2 ≤ 0.2V)

 

 

 

 

 

 

 

 

7

SGND

-

 

Signal Ground

 

 

 

 

 

 

When DTR/DSR is selected, this signal indicates whether the printer is

 

 

8

DR2

 

 

BUSY or READY. (H/W flow control)

 

 

Output

1)

DR1 > DR2 (H) : The printer is BUSY.

 

 

9

DR1

2)

DR1 < DR2 (H) : The printer is READY.

 

 

 

 

 

 

 

 

3)

The host computer transmits a data to the host,

 

 

 

 

 

 

 

after confirming this signal.

 

 

 

 

 

 

When DTR/DSR is selected, this signal indicates whether the host

 

 

10

CS2

Input

 

computer is BUSY or READY. (H/W flow control)

 

 

1)

CS1 > CS2 (H) : The host computer is BUSY.

 

 

11

CS1

 

 

 

2)

CS1 < CS2 (H) : The host computer is READY.

 

 

 

 

 

 

 

 

 

 

3)

The printer transmits a data to the host, after confirming this signal.

 

Table 3-17 RS-485 Pin Description

Note : BUSY condition and other information refer to the User’s Manual.

Note : This format is used when the UART for RS-232C is connected to the RS-485 driver.

3-5-2(e) H/W Flow Control

When DR1,2/CR1,2 flow control is select, before transmitting a data, the Printer checks whether the host is BUSY or not. If the host is BUSY, the Printer does not transmit a data to the host. If the host is not BUSY, the Printer transmits a data to the Host. The host is the same. Refer to the Interface Part of Chapter 4-3 Special Circuit Diagrams.

3-5-2(f) S/W Flow Control

When XON/XOFF flow control is selected, the printer transmits XON(ACSII 11h) or XOFF(ASCII 13h) signal through the TXD line. If the Printer is BUSY, the Printer transmits XOFF(ASCII 13h) to host through the TXD line. Then the host recognize that the Printer is BUSY. So, the host does not transmit a data to the Printer. If the Printer is released from BUSY, the Printer transmits XON(ASCII 11h) to host through the TXD line. Then the host recognize that the Printer is not BUSY. And the host transmit a data to the Printer.

Note : Refer to the Operation Manual about XON/XOFF flow control.

3-5-3 IEEE1284 Parallel Interface

Bidirectional parallel interface : in accordance with the IEEE1284 Nibble/Byte mode.

3-5-3(a) Forward Mode Specification (Compatibility mode)

Data transmission from host computer to printer : Centronics compatiable

Item

Description

Remark

Data Transmission

8-bit Parallel

 

Synchronization

• External supplied nStrobe signals

 

HandShaking

• nACK and Busy signals

 

Signal Level

• TTL compatiable

 

Connector

• Centronics 36P

 

 

Table 3-18 IEEE1284 Specification

 

Rev. 3.02

- 25 -

Page 25
Image 25