OEM-modeThe OEM_mode field is a 4 digit hexadecimal number. The number is defined as a bit field, each bit being a different option that is either enabled or disabled.

The following options are currently used :-

Bit Value Option

01 Login prompt uses OEM1 string

When set, and a custom language file is in use, the login prompt will use the string defined in the language file as the login prompt instead of the 'login: ' default prompt.

Note that this option applies to ealier versions of the software only.

12 Bypass Password

When set, authorised users who do not have a password set, with the exception of the admin account, WILL NOT be prompted for a password at login.

24 Disable Routed

When set, the routed process will not be started at boot time. Instead, a static route will be created using the first entry found in the gateways table that is set to type default.

38 Telnetp Single Connection

Sets all reverse connections ( raw and telnet ) to a one connection at a time mode. Server side applications will get a (socket) connection refused until :

All data from precious connections on that serial port have drained;

There are no other connections;

A (upto) 1 second interconnection poll timer has expired.

Black Box Console Server user guide