255.255.255.255 - specified by user. The unit will prompt the user for an IP address or hostname, when the telnet or rlogin service is started. When the user service is set to Telnet, Rlogin or TCP Clear, the unit will give the user two attempts the enter the required information.

n.n.n.n- (where ‘n’ is a number) you specify in this field the IP address of a host with which the unit should start the telnet or rlogin service for this user.

callback (callback for a user is also known as FIXED callback) the values are either ‘on’ or ‘off’ (default is off). When ‘on’ enter a phone number for the unit to call the user back; see the field ‘phone number’; (the callback setting is unrelated to the ‘dial’ parameter you can set for a line).

Note: the unit will only allow callback when a user is authenticated. If the protocol over the link does not provide authentication there will be no callback. Hence, when the line service is set to ‘PPP’ you must use either PAP or CHAP (see Configuring

PPPon page 82, sub-section ‘Security’), because these protocols provide authentication.

For a diagrammatic view of callback, see Callback for a user on page 105. Note that the unit supports another type of callback - ROAMING callback - which is configurable for a line when you are using the PPP protocol; see Configuring PPP on page 82.

Black Box Console Server user guide

103

Page 103
Image 103
Black Box 16 port, 24 port manual 103