Local ip This is the IP address of the unit end of the PPP link. For routing to work you must

address enter a local IP address. Choose an address which is part of the same network or subnetwork as the remote end; e.g. if the remote end is address 192.101.34.146, your local ip address may be 192.101.34.145; (in the cli, example syntax would be:

set ppp li 6 lipaddr 192.101.34.145)

To see an example of ip address usage, refer to ‘Setting up an IP address on page 33’. Do not use the unit’s (main) ip address in this field; if you do so, routing will not take place correctly.

Remote ip This is the IP address of the remote end of the PPP link. This must be specified.

address Choose an address which is part of the same network or subnetwork as the unit (see comment in ‘Local ip address’ above). Enter the remote ip address in dot notation, e.g.192.101.34.146; (or in the cli, example syntax would be: set ppp li 6 ripaddr 192.101.34.146).

If you set the PPP parameter ‘IP address negotiation’ to ‘on’ the unit will ignore the remote ip address value you enter here and will allow the remote end to specify its ip address.

If your user is authenticated by the unit this remote ip address will be overridden if you have set a ‘framed ip’ address for the user other than 255.255.255.254; see Configuring a user account on page 100, sub-section ‘framed ip’.

If your user is authenticated by RADIUS and the RADIUS parameter ‘Framed- Address’ is set in the RADIUS file the unit will use the value in the RADIUS file in preference to the ‘Remote ip address’ value configured here. The exception to this rule is a Framed-Address value in the RADIUS file of 255.255.255.254; this value allows the unit to use the remote ip address value configured here.

Subnet Mask This is the subnet mask of the node on the remote end of the PPP link. This field is optional. This parameter should be entered in dot notation e.g. 255.255.255.224 (or in the cli, e.g., set ppp li 9 255.255.255.224).

If your user is authenticated by RADIUS and the RADIUS parameter ‘Framed- Netmask’ is set in the RADIUS file the unit will use the value in the RADIUS file in preference to the ‘Subnet Mask’ value configured here.

Black Box Console Server user guide

83

Page 83
Image 83
Black Box 16 port, 24 port manual Black Box Console Server user guide