Example RADIUS user file: telnet service

davePassword = "garage" User-Service = Callback-login, Login-Host = 192.101.34.199, Login-Service = Telnet, Login-TCP-Port = 23,

Class = "Indirect Sales Group",

Session-Timeout = 1800,

Idle-Timeout = 600,

CallBack-Number = "3592"

An explanation of the file shown in Example RADIUS user file: telnet service on page

98 is as follows:

-the file contains a mixture of user parameters (e.g. callback-number) and line parameters (e.g. login-host).

-this user has been authenticated by RADIUS; therefore, all user parameters are passed down to the unit in this file.

-if you also have user ‘dave’ listed in the unit’s user table (i.e. a duplicate entry - we do not recommend this action) all the user parameters configured in the unit for user ‘dave’ will be overridden by the parameters in the RADIUS file; (for the user to be authenticated by the RADIUS host, where you have a duplicate entry, the password for ‘dave’ in the unit would have to be different to that entered in the RADIUS user’s database or authentication in the unit would have to be set to RADIUS (i.e. RADIUS only)).

-Class = "Indirect Sales Group" is a RADIUS class attribute. The unit can only process a string of maximum 32 characters; therefore limit your string to this size. In this example "Indirect Sales Group" is 20 characters (including spaces).

-line parameters override those configured in the unit; see Configuring a dial in line on page 74 for a more detailed discussion on line parameters.

Black Box Console Server user guide

97

Page 97
Image 97
Black Box 16 port, 24 port manual Example Radius user file telnet service