Chapter 6: Serial Control
6. Serial Control
Use the following parameters to control the ServSwitch DKM FX via its serial interface.
115.2K, 8, 1, NO
(115.2 kbps, 8 data bits, 1 stop bit, no parity)
Command
<STX>, <command byte (CMD)>, [data bytes (D0…DN)], <ETX>
[ ] = Optional elements
Response
<ACK> , [<ECHO>]
[ ] = Optional elements
<ECHO> reports the ServSwitch DKM FX sequences enabled by a command that shows the new switching status of the ServSwitch DKM FX. The echo can be used to update user applications and to operate several matrices in parallel.
Parameter Description
Command byte: In the range 0x40 to 0x6F (see the list of allowed commands below).
Data bytes: a) To prevent transferring control statements of control commands while transferring binary data, the data are divided into
=> 0x61 + 0x6F
b)
c)ASCII data => 0x20 to 0x7E are transmitted unencrypted.
Page 108 |