Table 4-14. Access settings.

 

 

 

Chapter 4: Configuration

 

 

 

 

 

 

 

 

Table 4-14. Access settings.

 

 

 

 

 

 

Field

Selection

Description

 

 

 

 

 

 

 

 

The user has to log in with a user name and a password code to enter

 

Enable User

Activated

OSD. Thereafter, the user remains logged in until he explicitly logs out

 

 

or an auto logout is effected.

 

Login

 

 

 

 

 

 

 

 

 

 

 

 

Deactivated

Function not active (default)

 

 

 

 

 

 

 

 

CPU access is restricted according to the permissions in the ACL

 

 

 

(Access Control List).

 

Enable User

Activated

• User login is required.

 

 

 

ACL

 

• Switching by keyboard hotkeys requires a prior login.

 

 

 

 

 

 

 

 

 

 

Deactivated

Function not active (default)

 

 

 

 

 

 

 

Activated

Upon opening the OSD, the console will automatically disconnect from

 

Auto

the current CPU.

 

 

 

Disconnect

 

 

 

 

Deactivated

Function not active (default)

 

 

 

 

 

 

 

 

OSD

0–999 seconds

Period of inactivity after which OSD will close automatically.

 

 

 

 

Timeout

• Select 0 seconds, for no timeout (default: 0 seconds)

 

 

 

 

 

 

 

 

 

 

 

 

 

Period of inactivity after which a user is automatically logged out from

 

 

 

the OSD at this console.

 

Auto Logout

0–999 minutes

• The timer is not active as long as the OSD is open.

 

 

 

 

 

 

• Select 0 minutes, for no timeout (default: 0 minutes)

 

 

 

 

 