Chapter 6: Serial Control

Table 6-20. Return of CON (Input) for CPU (Output) with a fixed CPU number.

Bytes

Description

Coding

 

 

 

1

Control character

0x1B

 

 

 

1

Server identification

0x5D

 

 

 

1

Command

0x53

 

 

 

2

Total length of telegram (7 bytes, binary)

0x07 0x00

 

 

 

2

Total number of CPUs

0x01 0x00 (for 1 CPU) to 0x11F 0x00 (for 287 CPUs)

 

 

 

Example:

Return of Console 23 for CPU 43 with 50 CPUs in total

0x1B 0x5D 0x53 0x07 0x00 0x32 0x00 0x2B 0x00 0x17 0x00

Table 6-21. Connection of CON (input) with CPU (output)

with a fixed total CPU number.

Bytes

Description

Coding

 

 

 

1

Control character

0x1B

 

 

 

1

Server identification

0x5B

 

 

 

1

Command

0x54

 

 

 

2

Total length of telegram (7 bytes, binary)

0x07 0x00

 

 

 

2

Total number of CPUs

0x01 0x00 (for 1 CPU) to 0x11F 0x00 (for 287 CPUs)

 

 

 

Example:

Connection of Console 23 with CPU 43 with 50 CPUs in total 0x1B 0x5B 0x54 0x07 0x00 0x32 0x00 0x2B 0x00 0x17 0x00