SERIES II INTELLIGENT DATA/FAX MODEMS

S30

Inactivity Timer

Unit:

Minutes

Range:

0-255

Default:

0

Description:

S30 causes the modem to disconnect if no data is

 

transmitted or received for a specified time. This

 

timer runs during both Reliable and Normal

 

error correction connections. The timer restarts

 

any time a data character is passed through the

 

serial port (either sent or received). If noise on

 

the phone line causes an error to be received

 

during Normal mode, this also restarts the timer.

 

The inactivity timer is disabled by setting S30 to

 

zero, which is the factory default setting.

S32

Time Elapse for Escape Sequence

Unit:

Seconds

Range:

0-255

Default:

20

Description:

S32 sets the time period to validate the escape

 

sequence. If the time interval expires before

 

the escape sequence is employed (by hitting

 

RETURN), the escape sequence is aborted.

 

The default time is 20 seconds.

S34

Buffer Length of Command Mode...After On-line Escape

Sequence

Unit:

ASCII characters

Range:

0-60

Default:

10

Description:

If the number of characters after AT exceeds the

 

S34 buffer length value, the buffer is cleared and

 

the escape sequence is aborted.