SERIES II INTELLIGENT DATA/FAX MODEMS

S19

Dial-Back Timer (336+ Only)

Unit:

Minutes

Range:

0-255

Default:

1

Description:

In the Series II Modem 336+ (MD1640A), S19

 

is a timer that begins when the lease line goes

 

down. S19 specifies the duration of time the

 

modem attempts to reestablish the lease line

 

connection.

S24

PBX/CBX Disconnect Drop Time for DSR/CTS/CD

Unit:

50-mSec intervals

Range:

0-255

Default:

20

Description:

Some PBX and CBX phone systems require the

 

modem’s DSR, CTS, and/or CD signal(s) to

 

behave in a certain manner when calls are

 

disconnected. The Series II Modem’s &R, &S,

 

and &C commands cause the modem to drop

 

these signal(s) for a specified time period upon

 

disconnect, and then bring the signal(s) up

 

again. S24 defines the length of time that the

 

signals drop. The default setting of 20 results in

 

a one-second drop time, which is what most

 

PBX/CBX systems with this requirement need.

S25

DTR Dropout Time

Unit:

100-mSec intervals

Range:

0 (50 mSec), 1-255

Default:

0

Description:

S25 defines the amount of time that DTR must

 

be dropped before the modem disconnects.

 

Typically, a disconnect occurs when DTR is

 

dropped for 50 milliseconds or more. This

98

Page 99
Image 99