Black Box MD1641A, MD1640A manual 160, #Xn

Models: MD1640A MD1641A

1 199
Download 199 pages 7.26 Kb
Page 161
Image 161

SERIES II INTELLIGENT DATA/FAX MODEMS

Command

Values

 

 

Description

 

Xn

n = 0,1,2,3 or 4

*X0 selects Basic Result Codes (w/o

 

 

 

 

CONNECT 1200, CONNECT 2400).

 

 

 

 

X1 selects Extended Result Codes

 

 

 

 

(w/CONNECT 1200, CONNECT 2400).

 

 

 

 

X2 selects Standard AT Command set

 

 

 

 

with NO DIAL TONE.

 

 

 

 

X3 selects Standard AT Command set

 

 

 

 

with BUSY.

 

 

 

 

X4 selects Standard AT Command set

 

 

 

 

with NO DIAL TONE and BUSY.

&Xn

n = 0, 1, or 2

*&X0 has sync clock controlled by DIP

 

 

 

 

switch.

 

 

 

 

&X1 forces external sync clocking.

 

 

 

 

&X2 forces slave sync clocking.

#Xn

n = 0 or 1

*#X0 selects single XOFF character sent

 

 

 

 

until XON level returns.

 

 

 

 

#X1 selects multiple XOFF characters

 

 

 

 

after buffer level is full.

Yn

n = 0 or 1

*Y0 disables sending or responding to

 

(In Dial Command) long space “break”.

 

 

 

 

Y1 enables sending or responding to long

 

 

 

 

space “breaks”.

Z

 

 

 

All configuration parameters are reset to

 

 

 

 

default values.

,

In Dial Command

Causes pause during dialing.

;

In Dial Command

Causes return to Command Mode after

 

 

 

 

dialing.

!

In Dial Command

Causes modem to flash On-Hook.

@

In Dial Command

Causes modem to wait for ringback, then

 

 

 

 

5 seconds of silence before processing

 

 

 

 

next part of command.

* Factory Default Setting

160

Page 161
Image 161
Black Box MD1641A, MD1640A manual 160, #Xn