SERIES II INTELLIGENT DATA/FAX MODEMS

S11

Tone Dialing: Tone Spacing and Duration

Unit:

Milliseconds (mSec)

Range:

1-255

Default:

70

Description:

S11 sets the speed of tone dialing (spacing and

 

tone duration times). The default value is

 

70 mSec, meaning that each tone is on for

 

70 mSec with a 70 mSec pause between each.

 

The minimum S11 value allowed by most

 

telephone systems is 50 mSec. Very few

 

telephone systems can handle anything faster

 

than that. The maximum S11 value is 255 mSec.

S13

Remote Configuration Escape Character

Unit:

Decimal equivalents of ASCII characters

Range:

0-127

Default:

37 (%)

Description:

S13 defines the remote configuration escape

 

character (which becomes your modem’s

 

remote configuration character). The default is

 

three percent symbols (%%%). When the S13

 

character is entered three consecutive times

 

from a remotely connected site, your modem

 

responds with its Remote Configuration

 

procedure.

S15

Callback Time Delay

Unit:

Seconds

Range:

10-255

Default:

20

Description:

S15 defines the time delay between Callback

 

attempts after initial passwords have been

 

exchanged between modems. Refer to Chapter 7

 

for Callback Security information.

96

Page 97
Image 97
Black Box MD1641A, MD1640A manual S11 Tone Dialing Tone Spacing and Duration, S13 Remote Configuration Escape Character