SERIES II INTELLIGENT DATA/FAX MODEMS

Table 7-2. Callback Password and Dial Back Phone Number Entry Procedures

Step

Procedure

1.Enter your modem's LOGIN Password (as selected in Table 7-1) by entering the following:

AT#Ixxxxxxxxxx<CR> (xxxxxxxxxx from Table 7-1)

Enter your modem's Setup Password (as selected in Table 7-1) by entering the following:

AT#Syyyyyyyyyy<CR>(yyyyyyyyyy from Table 7-1)

2.Enable the Callback Security feature by entering the following:

AT#DB2<CR>ÊorÊAT#DB1<CR>

The following message is displayed on your monitor:

Entering Callback Mode, current phone numbers will be erased. Do you want to continue? (Y/N)

3.Enter a Y or N and hit RETURN.

Note: If this is your first time into Callback Mode, we recommend answering Y to clear all previous Callback Passwords and phone numbers from memory.

4.Enter individual Callback Passwords for each of 30 different phone number memory locations as follows:

AT#CBN0xxxxxxxxxx<CR>

To enter Callback Password for the first location (a minimum 6 characters, up to a maximum of 10 characters must be used).

AT#CBN1xxxxxxxxxx<CR>

To enter Callback Password for the second location...etc (a minimum 6 characters, up to a maximum of 10 characters must be used).

Note: The first character of your first Callback Password must be non-numeric.

5.Enter individual phone numbers for each of the 30 memory locations as follows:

AT+ - DP...????N0 <CR> (number for location N0)