CHAPTER 7: Callback Security and Remote Configuration

7.3.2 Remote Configuration Procedures

The procedures for using the Remote Configuration features are the same whether or not a call originates from the remote modem. Once the modem is on-line, perform the procedures in Table 7-4.

Table 7-4 Remote Configuration Operation Procedures

StepProcedure

1.Remote Escape Configuration requires %%%AT<CR> to be sent if the default value in S-Register S13 has not been changed.

The modem responds with:

1.- DATA Mode

2.- COMMAND Mode

2.You then select 1 or 2. With 1, the modem goes back into data mode and with 2, the modem responds with the following:

Password>

3.Enter your Setup Password, and if the code is correct the modem responds with:

OK

You can now use any AT commands of the modem being remotely configured as if they were being entered locally. You cannot change the setup of the LOGIN Password until you enter the proper LOGIN Password.

4.When you are done entering AT commands and you want to exit, type AT0 and hit RETURN. The modem responds with:

1.DATA Mode

2.COMMAND Mode

5.Enter a 1 to go back on-line with your computer, or enter 2 and the correct password to talk to your modem.