CHAPTER 6: S-Registers

time an incoming ring signal is detected, S1 increases its value by one, up to a maximum of

255.If you set S1 to a value other than its default value of zero, or if the value is increasing with rings, this new value remains stored in S1 for eight seconds after the last ring is counted, after which time the value reverts to zero.

S2

Escape Code Character

Unit:

Decimal equivalents of ASCII characters

Range:

0-127

Default:

43 (+)

Description:

S2 defines the escape code character. The

 

default character is the plus (+) sign

 

(43 decimal), but may be set for any ASCII

 

character. Setting an S2 value greater than 127

 

results in no escape character, and therefore no

 

means of entering Command mode from On-

 

line mode without breaking the on-line

 

connection.

S3

Return Character

Unit:

Decimal equivalents of ASCII characters

Range:

0-127

Default:

13 (^M)

Description:

S3 defines the character recognized as Carriage

 

Return (RETURN) or “Enter”. S3 may be set for

 

any ASCII character.

S4

Line Feed Character

Unit:

Decimal equivalents of ASCII characters

Range:

0-127

Default:

10 (^J)

Description:

S4 defines the character recognized as Line

 

Feed. S4 may be set for any ASCII character.

93