SERIES II INTELLIGENT DATA/FAX MODEMS

Table 7-1. Modem LOGIN, Setup and Remote Escape Code Procedures

To change your modem’s LOGIN Password and Setup Password:

StepProcedure

Note: Passwords are upper/lower case sensitive. The case you enter here is the case that must be used at Log-In.

1.Type AT#IBLACK BOX and hit RETURN. Your modem will respond with:

OK (if the LOGIN Password is wrong, the modem’s response is

ERROR)

2.Type AT#SMODEMSETUP and hit RETURN. Your modem will re- spond with the following:

OK (or ERROR if wrong Setup Password)

Note: At this point you can change the LOGIN Password and Setup Password.

3.Type AT#I=xxxxxxxxxx (with any keyboard characters used, minimum 6 maximum 10) and hit RETURN. Your modem responds with:

OK

4.Type AT#S=yyyyyyyyyy (with keyboard characters used, minimum 6 maximum 10) and hit RETURN. Your modem responds with:

OK

To change your Remote Configuration feature status:

5.If you want Remote Configuration off, set S-Register S13 to 0 (zero). Refer to Chapter 6 for details on how to set S-Register values.

6.If you want Remote Configuration on and wish to change the Remote Escape Character, change the S-Register S13 value. If you leave it at the default value, decimal 37 (% sign) will be your modem’s remote escape character.

106

Page 107
Image 107
Black Box MD1641A, MD1640A manual Error, To change your Remote Configuration feature status