Black Box MD1640A, MD1641A manual S36 Time Between DTR Inactive and Modem Off-Hook

Models: MD1640A MD1641A

1 199
Download 199 pages 7.26 Kb
Page 102
Image 102

CHAPTER 6: S-Registers

S36

Time Between DTR Inactive and Modem Off-Hook

Unit:

Seconds

Range:

0-255

Default:

0

Description:

The DTR Busy-out feature uses S-Register S36 to

 

set the time between DTR inactive (low) and the

 

modem going off-hook. S36 can be set in one-

 

second intervals from 0 to 255 seconds. With the

 

default setting of S36=0, DTR Busy-Out is

 

disabled (i.e., DTR won't Busy-Out).

S37

Time Between DTR Active and Modem On-Hook

Unit:

Seconds

Range:

0-255

Default:

5

Description:

S37 sets the time between DTR being active and

 

the modem going on-hook(not busy). S37 will

 

only function in conjunction with S36.

S48

Program V.34bis Connect Speeds

Unit:

N/A

Range:

33, 31, 28, 26, 24, 21,19,16,14,12, 96, or 48

Default:

0

Description:

Defines which speed modem connects within

 

the scope of Enhanced V.34 mode (e.g., if S48 is

 

set to 26, the maximum connect speed will be

 

26.4K). This register compensates for line

 

conditions that have trouble supporting higher

 

Enhanced V.34 speeds (e.g., 33.6K, 31.2K, 28.8K,

 

26.4K, 24K...). The modem default is a value of

 

0, which indicates a connection attempt of

 

33.6K.

101

Page 102
Image 102
Black Box MD1640A, MD1641A S36 Time Between DTR Inactive and Modem Off-Hook, S37 Time Between DTR Active and Modem On-Hook