VideoJet 8008 / VideoJet 8004 Installation and Operating Manual

EN 141

 

 

 

 

 

Appendix

8

 

Troubleshooting

If you cannot resolve a fault, please contact your supplier or systems integrator or go directly to Bosch Security Systems Customer Service.

The version numbers of the internal processors can be viewed on a special page. Make a note of this information before contacting Customer Service.

In the address field of the browser, enter /version.htm after the unit's IP address (for example 192.168.0.88/version.htm).

Write down the information or print out the page.

The following table is intended to help you identify the causes of malfunctions and correct them where possible.

Malfunction

Possible causes

Solution

No connection

Incorrect cable connections.

Check all cables, plugs, contacts

between the unit and

 

and connections.

terminal program.

 

 

The computer's serial

Check the other serial interface.

 

 

interface is not connected.

 

 

 

 

 

Interface parameters do not

If necessary select a different

 

match.

interface and make sure that the

 

 

computer's interface parameters

 

 

match those of the unit. Try the

 

 

following standard parameters:

 

 

19,200 baud, 8 data bits, no parity,

 

 

1 stop bit. Next, disconnect the unit

 

 

from the power supply and

 

 

reconnect it again after a few

 

 

seconds.

 

 

 

No image

Camera error.

Connect local monitor to the

transmission to

 

camera and check the camera

remote station.

 

function.

 

 

 

 

Faulty cable connections.

Check all cables, plugs, contacts

 

 

and connections.

 

 

 