VideoJet 8008 / VideoJet 8004 Installation and Operating Manual | EN 93 |
|
|
Video input:
The number of the associated video input and the stream used for the recording are displayed here. The numbering is the same as the labeling of the video inputs on the rear panel of the unit.
Note
On Dual Streaming compatible units, stream 2 is always used for the re- cording.
Type of recording:
Select the required recording type.
In the case of Ring mode the recording proceeds continuously. If the maximum hard drive space has been reached, the oldest recordings are automatically overwritten.
In the case of Linear mode the recording proceeds until the entire hard drive space is full. The recording is then stopped until old recordings have been deleted.
Video recording:
The recording format is displayed here for information.
Recording profile:
Select the profile that is to be active during recording. You can view and modify the parameters for the profile (see
Note
The recording profile can differ from the standard setting Active profile for the video input set and is only used during an active recording.
Alarm recording at:
You can select the alarm sensor that is to trigger a recording. You can also use the motion and video alarm for a camera to trigger the alarm recording by another camera.
Note
The alarm sensor must be active to be able to trigger the recording. The alarm inputs and video loss alarms are activated on the Alarm sources page (see page 95). The motion alarms are configured and activated for each camera on the Motion detector page (see page 99).
Bosch Security Systems | Configuration using a Web browser |