EN 42 | Installation and Operating Manual VideoJet 8008 / VideoJet 8004 |
|
|
Alarm recording
Here, you can specify the times during which continuous recording to the hard drives should take place in the event of an alarm.
As with time recording, there are separate selection fields for each partition and thus for each camera input. You can select up to 16 separate periods for each day of the week. Alarm recording occurs only during the highlighted time intervals.
Note
If a period is already selected for time recording, you cannot select it for alarm recording (see Time recording, page 40).
Caution
Alarm tracks must be set up in the required partition for alarm recording (see Number of alarm tracks, page 43).
The unit uses a special recording mode during alarm recording for optimal usage of storage capacity: as soon as a time gap for alarm recording begins, a recording is continuously made on one segment, which is the size of a complete alarm sequence (pre- and