EN 18 | Installation and Operating Manual VideoJet 8008 / VideoJet 8004 |
|
|
Installing in a switch cabinet
VideoJet 8008 and VideoJet 8004 are set up for installation in a
Caution
When installing in a switch cabinet, ensure that there is sufficient ventilation for each unit: There must be at least 5 cm (1.97 in.) of free space to the left and right of the unit and at least 10 cm (3.94 in.) at the rear.
The ambient temperature must be between 0 and +40 °C
(+32 and +104 °F), and the relative humidity must not exceed 80%.
The unit heats up during operation, so you should ensure that there is enough clearance between the unit and other
When mounting additional units, direct contact is permitted, provided that the surface temperature of the adjacent units does not exceed +40 °C (+104 °F).
Installing the unit
–On the left and
–Insert the two angle brackets from the mounting kit into the slots next to the screw holes on the housing and secure them with the four housing screws.
–Set the unit in the switch cabinet frame and secure the angle brackets using the four screws, washers and lock nuts provided.
–Connect the rubber connector of the power cable supplied to the Power socket on the rear panel of the unit.