| VideoJet 8008 / VideoJet 8004 Installation and Operating Manual | EN 17 | |
|
|
|
|
| Installation | 4 |
|
VideoJet 8008 and VideoJet 8004 are designed as desktop units and intended for installation in a switch cabinet. Mounting in a
For desktop operation, four
Caution
The unit is designed for indoor operation. Select a suitable location for installation where the unit will not be subjected to conditions of extreme temperature or humidity. The ambient temperature must be between 0 and +40 °C (+32 and +104 °F), and the relative humidity must not exceed 80%
The unit heats up during operation, so you should ensure that there is adequate ventilation and enough clearance between the unit and
Please ensure the following installation conditions:
❚Do not install the unit close to heaters or other heat sources. Avoid locations exposed to direct sunlight.
❚Allow sufficient space for running cables.
❚Ensure that the unit has adequate ventilation. Bear the total heat output in mind, particularly when installing multiple units in a switch cabinet.
❚When making connections, use only the cables supplied or use appropriate cables immune to electromagnetic interference.
❚Position and run all cables so that they are protected from damage, and pro- vide adequate cable strain relief where needed.
❚Avoid impacts, blows and severe vibrations as these can irreparably damage the unit.
Bosch Security Systems | Installation |