Bosch Appliances Walk Test CMD + 4 +, D1265 | Owners Manual | Part II: System Commands

Models: D1265

1 92
Download 92 pages 19.67 Kb
Page 24
Image 24
Walk Test (CMD + 4 + 4)

D1265 Owner's Manual Part II: System Commands

If there are no events to view, There are currently no events in memory shows.

6.You can return to idle text at any time by pressing Exit button.

Walk Test (CMD + 4 + 4)

Description

Use this function to test keypads, detection devices, and sounders (both interior and exterior) to be certain they function properly. You can review untested points at your keypad to help pinpoint any problems.

You cannot arm your system while in the walk test mode, and no alarm reports are sent to your security company unless a 24-hour point is activated (such as fire or panic). A Walk Test Start Report might be programmed to be sent to your security company.

Upon initiation, the walk test tests the burglary bell pattern on the bell output and ring the keypad burglary bell for 2 sec. The AC is disabled for 4 minutes in order to test the system’s battery power. If the battery cannot maintain the system for the 4- minute period, the keypad appears to power off. If your keypads are programmed to be supervised, the main alarm panel piezo intermittently during this 4- minute period. If this happens, contact your security company. At the end of the 4-minute period, AC is returned to the system and the control panel restores. To test individual detection devices, simply activate sensors and open protected doors and windows one-at- a-time. As each detection device is faulted, the keypad emits a brief tone and the display indicates for 60 sec that the point has been tested. This verifies that each detection device is working properly.

Using Walk Test

1.Ensure the display shows disarmed idle text.

2.Press the CMD button. The display shows *System Command*.

If you prefer, you might use the function list in place of Steps 2 and 3 to initiate this function.

Press the Menu button to enter the function list.

Press the Next button repeatedly.

When you reach the Walk Test button, press it.

4.The burglary bell sounds for 2 sec. When the display shows ### points remain to be tested (### is the number of points) you can begin.

Test each point by first opening and then closing the door or window, or activating the other detection device types.

Check the display after testing each point. For interior points, walking past the device once is sufficient. If any point will not test correctly, contact your security company for service.

5.During the Walk Test you might want to refer to the points that remain untested by pressing the View untested pts button.

The display shows ### pts untested.

Press the Next Pt or Prev Pt buttons to refer to information about specific points that have not yet been tested.

3.Press the 4 button and then the 4 button.

24

Bosch Security Systems, Inc. 9/10 F01U169130-02

Page 24
Image 24
Bosch Appliances Walk Test CMD + 4 +, D1265 | Owners Manual | Part II: System Commands, Description, Using Walk Test