12.5.2 Network Interface Modules

D9412GV3/D7412GV3 Operation and Installation Guide 12.0 SDI Devices

12.5.2 Network Interface Modules

The Bosch Security Systems, Inc. DX4020 Network Interface Module is a four-wire powered SDI device that provides connection for two-way communication over Ethernet networks to D9412GV3 and D7412GV3.

For programming information on enhanced communications, refer to the D9412GV3/D7412GV3 Program Entry Guide (P/N: F01U170807).

The DX4020 can be installed up to 305 m (1000 ft) from the control panel using 0.8 mm (22 AWG) wire.

The ITS-DX4020-G GPRS/GSM IP Communicator enables two-way IP or dialed communication over a commercial GPRS/GSM network. Typical applications are event reporting to a central monitoring station and remote access to Bosch intrusion control panels.

The ITS-DX4020-G GPRS/GSM IP Communicator has two modes; GPRS uses Modem IIIa2; and GSM uses Contact ID.

For programming information refer to the ITS-DX4020-G GPRS/GSM IP Communicator Installation and Operation Guide (P/N: F01U163066).

12.5.3 Address Settings

The DX4020 has specific DIP switch settings for SDI Addresses 88 and 92 when using the DX4020 for Remote Programming Software (RPS) or enhanced communications in a local-area network (LAN) or wide-area network (WAN) environment. Refer to Figure 30 for the correct switch settings.

Figure 30: DX4020 DIP Switch Settings

1 - DIP Switches

2 - ON position

3 - OFF position

4 - SDI Address 80 switch settings

5 - SDI Address 88 switch settings

6 - SDI Address 92 switch settings

12.5.4 Supervision

Supervision of the DX4020 and D9133DC at SDI Address 88 and 92 is available through programming that ensures operation between the module and the control panel.

If supervised and the module does not respond to control panel supervision polls, SERVC SDI 88 or SERVC SDI 92 appears at the keypad. The report to the receiver includes the address of the troubled module indicating which module needs service.