Bosch Appliances D7412GV3, D9412GV3 manual Battery Terminals, Non-Power-LimitedWiring, Power Supply

Models: D9412GV3 D7412GV3

1 76
Download 76 pages 25.33 Kb
Page 23
Image 23
Figure 7: Battery Terminals

D9412GV3/D7412GV3 Operation and Installation Guide

5.0

Power Supply

 

 

 

3.Connect the black battery lead to Terminal 4, and then to the negative (-) side of the battery.

4.Connect the red battery lead to Terminal 5, and then to the positive (+) side of the battery.

Warning: High current arcs are possible. The positive (red) battery lead and Terminal 5 can create high current arcs if shorted to other terminals or the enclosure. Use caution when working with the positive lead and Terminal 5. Always disconnect the positive (red) lead from the battery before removing it from Terminal 5.

Caution: The battery terminals and wire are not power limited. A 6.4 mm (0.250 in.) space must be maintained between the battery terminals, battery wiring, and all other wiring. Battery wiring cannot share the same conduit, conduit fittings, or conduit knock-outs with other wiring.

Figure 7: Battery Terminals

1 - Battery terminals. Terminal 5 is non-power limiting.

 

Figure 8: Non-Power-Limited Wiring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 - Conduit required for use with external batteries.

4 -

Relay output wires

 

 

2 - Battery wires

5 - Input or Zone wires

 

 

3 - 6.4 mm (0.25 in.) minimum. To ensure proper

6 -

Standby battery

 

 

spacing, use tie-wraps or similar devices to

 

 

 

 

secure wires.

 

 

 

 

 

 

 

 

 

Bosch Security Systems, Inc. 10/10 F01U143070-03

 