Bosch Appliances D7412GV3 3.0Overview, 3.1Configuration and Parts, System Configuration, Features

Models: D9412GV3 D7412GV3

1 76
Download 76 pages 25.33 Kb
Page 9
Image 9
Overview

D9412GV3/D7412GV3 Operation and Installation Guide

3.0

Overview

 

 

 

3.0Overview

3.1Configuration and Parts

Figure 1: System Configuration

D9210B Modules can be used for access control.

Each D8128D OctoPOPIT combines eight POPIT points in one module.

D8129 OctoRelay provides alarm and auxiliary relay output.

(Other functions available.)

DX4020 or ITS-DX4020-G allows communciation over a Local or Wide Area Network (LAN/WAN).

D8125, ISW-D8125CW-V2 or D8125MUX Interface used for point expansion.

Control

Panel

On-Board Points

1 to 8

D928 Module allows the control panel to monitor two phone lines.

Use keypads or keyswitches to arm the control panel by area. The D9412GV3 control panel supports up to 32 areas. The D7412GV3 control panel supports up to 8 areas. Each area can have its own account number or areas can be grouped together with a common account number. Points of protection are assigned to areas.

D8132 Modules (two 12 VDC batteries) provide additional power for keypads and other powered devices.

D9131A Module connects to a parallel printer to print the event log.

Table 2: GV3 Series Control Panel Differences
Features
D9412GV3
D7412GV3

 

 

 

Access Control

Yes - 8 doors

Yes - 2 doors

Arm/Disarm Passcodes

249

99

Cards/Tokens

996

396

Passcode-Protected Custom Functions

16

4

 

 

 

Number of Printers

3

1

Number of Points

246

75

 

 

 

Number of Relays

128

64

Number of Areas

32

8

 

 

 

Number of D1255 Keypads

16

16

Number of D1260 Keypads

8

8

 

 

 

D7212GV3

No

99

N/A

4

1

40

24

4

8

8

Bosch Security Systems, Inc. 10/10 F01U143070-03

9

Page 9
Image 9
Bosch Appliances D7412GV3 3.0Overview, 3.1Configuration and Parts, System Configuration, Features, D9412GV3, D7212GV3