13.0Programmer and Accessory Connections

D9412GV3/D7412GV3 Operation and Installation Guide 13.0 Programmer and Accessory Connections

13.0Programmer and Accessory Connections

13.1Programmer Connector

Control panel firmware version 8.11 and later does not support the D5200 Programmer. Instead, a limited local keypad programming mode is available. Refer to Section 13.2 Installer Keypad and Local Programmers Mode on page 62 for details.

Figure 31: Reset Pin

1 - Reset Pin locked (closed)

2 - Reset Pin normal (open) for normal control panel operation

When the Reset Switch (labeled S1) is closed, the communication module at SDI Address 92 is disabled. While in this mode, remote programming communication is only supported by the communication module at SDI Address 88.

13.2Installer Keypad and Local Programmers Mode

While installing or maintaining a D9412GV3 or D7412GV3 control panel, it is sometimes necessary to change the configuration. To do so, a local keypad programming menu is available in the Service Menu. You can access the Service Menu when the control panel is in stand-by mode or while it is operating. Refer to the D9412GV3/D7412GV3 Control Panel Program Entry Guide (P/N: F01U170807) for an explanation of the programming menu.

Accessing Local Keypad Programming when the Control Panel is Operating (Reset Switch Open)

To access the Local Programmers Menu while the control panel is operating:

1.Disarm all areas in the control panel.

Local keypad programming is only accessible when all areas are disarmed.

2.At any D1255 or D1260 Keypad, press [9][9][ENTER] to access the Service Menu.

3.Enter the Service passcode when prompted.

4.Advance the menu to the Keypad Programming option, then press [ENTER] to enter programming mode.

The Keypad Programming menu is only available when all areas in the control panel are disarmed.

Accessing Local Keypad Programming when the Control Panel is in Standby Mode (Reset Switch Closed)

The control panel is in standby mode when the Reset pin is closed. Refer to Figure 31. While the control panel is in standby mode, you can access the Service Menu at one of two keypads with the following restrictions:

An unsupervised D1260 Keypad (all versions) at SDI Bus Address 8.

The D1260 Keypad does not support SDI Bus Address 16.

An unsupervised D1255 Keypad (all versions) at SDI Bus Address 16.

If a D1255 is set to SDI Bus Address 8, then that keypad cannot be used to access the Service Menu.

Only one keypad at a time is allowed to be in use.

To access Local Keypad Programming when the control panel is in standby mode:

1.From the keypad (D1260 at SDI Address 8 or D1255 ad SDI Address 16), enter the Service Passcode.

2.Advance the menu to the Keypad Programming option.

3.Press [ENTER] to enter Local Keypad Programming.

13.3Programmer Access Reports

When a program is sent to the control panel from RPS, the control panel sends a Prog Access OK report 10 sec after the reset switch is unlocked, or when the programmer disconnects. The prompt in routing must be programmed Yes to send this report.