VideoJet X10Appendix en 113

Malfunction

Possible causes

Recommended solution

 

 

 

The unit does not report

Alarm source is not selected.

Select possible alarm sources on

an alarm.

 

the Alarm Sources configuration

 

 

page.

 

 

 

 

No alarm response specified.

Specify the desired alarm

 

 

response on the Alarm

 

 

Connections configuration page,

 

 

change the IP address if

 

 

necessary.

 

 

 

Control of cameras or

The cable connection between

Check all cable connections and

other units is not

the serial interface and the

ensure all plugs are properly

possible.

connected unit is not correct.

fitted.

 

 

 

 

The interface parameters do not

Make sure that the settings of all

 

match those of the other unit

units involved are compatible.

 

connected.

 

 

 

 

The unit is not

Power failure during

Have the unit checked by

operational after a

programming by firmware file.

Customer Service and replace if

firmware upload.

 

necessary.

 

 

 

 

Incorrect firmware file.

Enter the IP address of the unit

 

 

followed by /main.htm in your

 

 

Web browser and repeat the

 

 

upload.

 

 

 

Bosch Security Systems

Installation and Operating Manual

V3.0 2007.09