VideoJet X10Appendix en 117

8.7

Terminal Block

The terminal block has several contacts for:

4 alarm inputs

4 relay outputs

Serial data transmission

8.7.1Pin Assignment

The pin assignment of the serial interface depends on the interface mode used (see

Abschnitt 5.27 COM1, Seite 75).

Contact

RS232 mode

RS422 mode

RS485 mode

 

 

 

 

CTS

CTS (clear to send)

RxD- (receive data minus)

Data-

 

 

 

 

TXD

TxD (transmit data)

TxD- (transmit data minus)

 

 

 

 

 

RTS

RTS (ready to send)

TxD+ (transmit data plus)

Data+

 

 

 

 

RXD

RxD (receive data)

RxD+ (receive data plus)

 

 

 

 

 

GND

GND (ground)

 

 

 

 

Contact

Function

 

 

IN1

Input alarm 1

 

 

IN2

Input alarm 2

 

 

IN3

Input alarm 3

 

 

IN4

Input alarm 4

 

 

GND

Ground

 

 

R1

Relay output 1

 

 

R2

Relay output 2

 

 

R3

Relay output 3

 

 

R4

Relay output 4

 

 

RM1

LED remote indicator

 

 

RM2

LED remote indicator

 

 

BP

Backup power supply

 

 

GND

Ground

 

 

+

10 to 30 V (power supply)

 

 

Ground

 

 

Connect each alarm input to a ground contact (GND) when connecting alarm inputs.

For the RM1 and RM2 contact specifications, see Abschnitt 4.3.10 Remote Indication of the Connection Status, Seite 23.

For the backup power supply specifications, see Abschnitt 4.3.11 Backup Power Supply, Seite 24.

Bosch Security Systems

Installation and Operating Manual

V3.0 2007.09