78 en Configuration Using a Web Browser

VideoJet X10

 

 

Changes to fields followed by the Reboot link are transmitted to the unit by clicking the Set button; however, they will only be activated once the unit is rebooted.

1.Make the desired changes.

2.Click the Set button.

3.Click a Reboot link to trigger a reboot. VideoJet X10 is rebooted and the changed settings are activated.

CAUTION!

! If you change the IP address, subnet mask or gateway address, the VideoJet X10 is only available under the new addresses after the reboot.

5.28.1

IP address

 

Enter the desired IP address for the VideoJet X10. The IP address must be valid for the

 

network.

5.28.2

Subnet mask

 

Enter the appropriate subnet mask for the selected IP address here.

5.28.3

Gateway address

 

If you want the unit to establish a connection to a remote location in a different subnet, enter

 

the IP address of the gateway here. Otherwise leave the box blank (0.0.0.0).

5.28.4

DNS server address

 

The VideoJet X10 is easier to access if the unit is listed on a DNS server. If you wish, for

 

example, to establish an Internet connection to the VideoJet X10, it is sufficient to enter the

 

name given to the unit on the DNS server as a URL in the browser. Enter the DNS server's IP

 

address. Servers are supported for secure and dynamic DNS.

5.28.5

Video transmission

 

If the unit is operated behind a firewall, TCP (HTTP Port) should be selected as the transfer

 

protocol. For use in a local network, select UDP.

CAUTION!

!Multicast operation is only possible with the UDP protocol. The TCP protocol does not support multicast connections.

The MTU value in UDP mode is 1,514 bytes.

5.28.6HTTP browser port

Select a different HTTP browser port from the list if required. The default HTTP port is 80. If you want to allow only secure connections via HTTPS, you must deactivate the HTTP port. In this case, select Off.

V3.0 2007.09

Installation and Operating Manual

Bosch Security Systems