VideoJet X10

Installation en 21

 

 

4.3.4SFP Slot

 

You can establish an additional network connection by inserting a mini-GBIC module into the

 

SFP slot for example via fiber optic cables (OF).

 

 

!

CAUTION!

Only laser class 1 transceivers are approved for use in the VideoJet X10.

Use only approved modules.

 

 

4.3.5

Direct iSCSI Connection

 

You can connect the VideoJet X10 directly to an iSCSI system via one of the network

 

interfaces. For ETH 1 or ETH 2 connections, use a UTP category 5 network cable with RJ45

 

plugs.

 

 

i

NOTICE!

You can obtain a list of compatible iSCSI systems from your supplier or directly from Bosch

Security Systems. This list is constantly being updated and extended.

 

 

4.3.6

CF Slot

 

You can insert a type I or II CompactFlash card into the Compact Flash slot to enable

 

recordings to be saved locally. CF cards are the ideal solution for shorter storage times and

 

temporary recordings, for example alarm recordings or local buffering in the event of network

 

interruptions.

 

The VideoJet X10 supports high-performance CF cards with a storage capacity of up to 8 GB.

 

 

i

NOTICE!

You can obtain a list of compatible CF cards from your supplier or directly from Bosch

Security Systems. This list is constantly being updated and extended.

 

 

 

Playing back recordings is also possible using a different VideoJet X10, a VideoJet X20 or a

 

VideoJet X40.

 

 

 

CAUTION!

!Setting up partitions clears all existing data from the card.

You should therefore check whether the CF card contains any data that needs to be backed up before it is inserted.

1.Carefully slide the CF card, top side down, into the slot as far as it will go.

2.To remove the CF card, push the eject button to its right and then take out the card.