4.3.7Data Interface

The bidirectional data interface is used to control units connected to the VideoJet X10, for example a dome camera with motorized lens. The connection supports the RS232, RS422 and RS485 transmission standards.

The VideoJet X10 offers the serial interface via the orange terminal block (see Abschnitt 8.7 Terminal Block, Seite 117).

The range of controllable equipment is expanding constantly. The manufacturers of the relevant equipment provide specific information on installation and control.

 

CAUTION!

!

Please take note of the appropriate documentation when installing and operating the unit to

be controlled.

The documentation contains important safety instructions and information about permitted

 

uses.

 

 

 

i

NOTICE!

 

A video connection is necessary to transmit transparent data.

 

 

 

 

 

4.3.8

 

Alarm Inputs

 

 

The VideoJet X10 has four alarm inputs on the orange terminal block (see

 

 

Abschnitt 8.7 Terminal Block, Seite 117). The alarm inputs are used to connect to external

 

alarm devices such as door contacts or sensors. When configured appropriately, an alarm

 

device can, for example, trigger the VideoJet X10 to automatically establish a connection with

 

a remote station.

 

A zero potential make contact or switch can be used as the actuator.

 

 

i

NOTICE!

If possible, use a bounce-free contact system as the actuator.

 

 

 

 

X Connect the lines to the appropriate terminals on the orange terminal block (IN1 to IN4)

 

and check that the connection is secure.