58 en Configuration Using a Web Browser | VideoJet X10 |
|
|
5.19.1Standard profile
From this field, you can select the encoder profile to be used for continuous recording (see Section 5.11 Encoder Profile, page 38).
i | NOTICE! |
The recording profile can deviate from the standard setting Active profile and is only used | |
during an active recording. | |
|
|
5.19.2 | Encoder |
| Here you can select the data stream to be used for the recording. |
5.19.3 | Alarm track recording |
|
|
i | NOTICE! |
This parameter is active only if alarm tracks have been configured (see Section 5.18.8 Number | |
of alarm tracks, page 55). |
XClick the checkbox to activate alarm track recording. The
5.19.4Post-alarm time
You can select the required
5.19.5Post-alarm profile
You can select the encoder profile to be used for recording during the
The Standard profile option adopts the selection for continuous recordings at the top of the page.
5.19.6Alarm input / Motion alarm / Video loss alarm
Here you can select the alarm sensor that is to trigger a recording.
| NOTICE! |
| The motion alarm is configured and activated on the VCA page (see Section 5.23 VCA, |
i | |
The alarm inputs are configured and activated on the Alarm sources page (see | |
| The numbering of the checkboxes for the alarm inputs corresponds to the labeling of the |
| alarm inputs on the VideoJet X10. |
|
|
V3.0 2007.09 | Installation and Operating Manual | Bosch Security Systems |