106 en AppendixVideoJet X10 SN
8.3 | Malfunctions with iSCSI Connections |
| ||
|
|
|
|
|
|
| Malfunction | Possible causes | Recommended solution |
|
|
|
|
|
|
| After connecting to the | Incorrect LUN mapping during | Check the iSCSI system |
|
| iSCSI destination, no | iSCSI system configuration. | configuration and reconnect. |
|
| LUNs are displayed. |
|
|
|
|
|
|
|
|
| After connecting to the | The LUN list could not be read, | Check the iSCSI system |
|
| iSCSI destination, "LUN | as it was assigned to the wrong | configuration and reconnect. |
|
| FAIL" appears below a | network interface. |
|
|
| node. |
|
|
|
|
|
|
|
|
| LUN mapping is not | Some iSCSI systems do not | Delete the initiator extension on |
|
| possible. | support the use of an initiator | the Identification configuration |
|
|
| extension. | page. |
|
|
|
|
|
DOC V4.0 2009.06 | Installation and Operating Manual | Bosch Security Systems |