54 en Configuration Using a Web BrowserVideoJet X10 SN

 

2.

If necessary, click the Default button to return all settings to their default values.

 

3.

Click the Copy Settings button if you want to copy the currently visible settings to other

 

 

profiles. A new window will open and you can select the profiles in which you want to

 

 

copy the settings.

 

4.

For each profile, click the Set button to save the settings in the unit.

 

Standard recording

 

Here you can select the mode for standard recordings.

 

If you select Continuous, the recording proceeds continuously. If the maximum memory

 

capacity is reached, older recordings will automatically be overwritten. If you select the Pre-

 

alarm option, recording will only take place in the pre-alarm time, during the alarm and during

 

the set post-alarm time.

 

If you select Off, no automatic recording takes place.

 

 

!

CAUTION!

You can specify limitations for overwriting older recordings in Continuous mode by

configuring the retention time (see Section 5.24 Advanced Mode: Retention Time, page 55).

 

 

 

Standard profile

 

From this field, you can select the encoder profile to be used for recording (see

 

Section 5.19 Advanced Mode: Encoder Profile, page 46).

 

 

i

NOTICE!

The recording profile can deviate from the standard setting Active profile and is only used

during an active recording.

 

 

 

Pre-alarm time

 

You can select the required pre-alarm time from the list field.

 

Post-alarm time

 

You can select the required post-alarm time from the list field.

 

Post-alarm profile

 

You can select the encoder profile to be used for recording during the post-alarm time (see

 

Section 5.19 Advanced Mode: Encoder Profile, page 46).

 

The Standard profile option adopts the selection at the top of the page.

 

Alarm input / Motion alarm / Video loss alarm

 

Here you can select the alarm sensor that is to trigger a recording.

 

 

 

NOTICE!

 

The motion alarm is configured and activated on the VCA page (see Section 5.31 Advanced

i

Mode: VCA Event Triggered, page 68).

The alarm inputs are configured and activated on the Alarm Inputs page (see

Section 5.35 Advanced Mode: Alarm Inputs, page 73).

The numbering of the checkboxes for the alarm inputs corresponds to the labeling of the alarm inputs on the VideoJet X10 SN.

Virtual alarm

Here you can select the virtual alarm sensors that are to trigger a recording, via RCP+ commands or alarm scripts, for example.

DOC V4.0 2009.06

Installation and Operating Manual

Bosch Security Systems

Page 54
Image 54
Bosch Appliances X10 SN manual Standard recording, Standard profile, Pre-alarm time, Post-alarm time, Post-alarm profile