VideoJet X10 SN

Configuration Using a Web Browser en 59

 

 

By setting Follows input 1 the unit maintains the connection that has been automatically established for as long as an alarm exists on alarm input 1.

NOTICE!

i In the default setting, Stream 2 is transmitted for alarm connections. Bear this fact in mind when assigning the profile (see Section 5.19 Advanced Mode: Encoder Profile, page 46).

Number of destination IP address

Specify the numbers of the IP addresses to be contacted in the event of an alarm. The unit contacts the remote stations one after the other in the numbered sequence until a connection is made.

Destination IP address

For each number, enter the corresponding IP address for the desired remote station.

Destination password

If the remote station is password protected, enter the password here.

In this page, you can save a maximum of ten destination IP addresses and hence up to ten passwords for connecting to remote stations. If connections to more than ten remote stations are to be possible, for example when initiating connections via higher-ranking systems such as VIDOS or Bosch Video Management System, you can store a general password here. The VideoJet X10 SN can use this general password to connect to all remote stations protected with the same password. In this case, proceed as follows:

1.Select 10 from the Number of destination IP address list field.

2.Enter the address 0.0.0.0 in the Destination IP address field.

3.Enter your chosen password in the Destination password field.

4.Define this password as the user password for all remote stations to which a connection is to be possible.

NOTICE!

i

If you enter the destination IP address 0.0.0.0 for destination 10, this VideoJet X10 SN

 

 

address will no longer be used for the tenth attempt at automatic connection in the event of

 

an alarm. The parameter is then used only to save the general password.

 

 

Video transmission

If the unit is operated behind a firewall, TCP (HTTP port) should be selected as the transfer protocol. For use in a local network, select UDP.

CAUTION!

Please note that in some circumstances, a larger bandwidth must be available on the network

! for additional video images in the event of an alarm, in case Multicast operation is not possible. To enable Multicast operation, select the UDP option for the Video transmission parameter here and on the Network page (see Section Video transmission, page 77).

Remote port

Depending on the network configuration, select a browser port here. The ports for HTTPS connections will be available only if the On option is selected in the SSL encryption parameter.