5.35

Advanced Mode: Alarm Inputs

You can configure the alarm inputs of the VideoJet X10 SN.

Alarm input

Select Active high if the alarm is to be triggered when the contact closes. Select Active low if the alarm is to be triggered when the contact opens.

Name

You can enter a name for each alarm input, which is then displayed below the icon for the alarm input on the LIVEPAGE if configured correctly (see Section 5.15 Advanced Mode: LIVEPAGE Functions, page 42).

5.36

Advanced Mode: Relay

You can configure the switching behavior of the relay outputs. For each relay, you can specify an open switch relay (normally closed contact) or a closed switch relay (normally open contact).

You can also specify whether an output should operate as a bistable or monostable relay. In bistable mode, the triggered state of the relay is maintained. In monostable mode, you can set the time after which the relay will return to the idle state.

You can select different events that automatically activate an output. It is possible, for example, to turn on a floodlight by triggering a motion alarm and then turning the light off again when the alarm has stopped.

Idle state

Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is to operate as an NC contact.

Bosch Security Systems

Installation and Operating Manual

DOC V4.0 2009.06

Page 73