VideoJet X20

Installation en 19

 

 

4Installation

4.1Preparations

The VideoJet X20 features industrial standard equipment and is therefore suitable for both stationary installation and mobile installation in vehicles.

CAUTION!

The unit is intended for use indoors or in housings.

Select a suitable location for installation that guarantees to meet the environmental

!conditions. The ambient temperature must be between –30 and +60 °C (–22 and +140 °F). The relative humidity must not exceed 95%.

The VideoJet X20 generates heat during operation, so you should ensure that there is adequate ventilation and enough clearance between the unit and heat-sensitive objects or equipment.

Please ensure the following installation conditions:

Do not install the unit close to heaters or other heat sources. Avoid locations exposed to direct sunlight.

Allow sufficient space for running cables.

Ensure that the unit has adequate ventilation.

When making connections, use only the cables supplied or use appropriate cables immune to electromagnetic interference.

Position and run all cables so that they are protected from damage, and provide adequate cable strain relief where needed.

Avoid impacts, blows and severe vibrations that exceed the specification limits (see Section 10 Specifications, page 123), as these can irreparably damage the unit.

4.2Mounting

The VideoJet X20 can be permanently mounted to walls, below ceilings or other load-bearing locations using the four drillings in the unit's base.

CAUTION!

The front panel of the VideoJet X20 (video inputs) must not be pointing upwards, as internal heat dissipation is not guaranteed in this position. All other installation positions are permitted.

!Make sure that the mounting location (for example wall or ceiling) can reliably hold the unit. The load bearing capacity must be adequate for four times the weight of the unit.

For mounting on metal, use screws with the following minimum specification:

M4 × 8, 8.8, DIN ISO 4017.

For mounting on concrete, use screws with the following minimum specification:

M4 × 40 mm (1.57 in) and 6 mm (0.23 in) plastic dowels, for example fischer S4, type 50106.

Bosch Security Systems

Installation and Operating Manual

V3.5 2007.12