5.26 | Relay Settings |
You can configure the switching behavior of the relay outputs. For each relay, you can specify an open switch relay (normally closed contact) or a closed switch relay (normally open contact).
You can also specify whether an output should operate as a bistable or monostable relay. In bistable mode, the triggered state of the relay is maintained. In monostable mode, you can set the time after which the relay will return to the idle state.
You can select different events that automatically activate an output. It is possible, for example, to turn on a floodlight by triggering a motion alarm and then turning the light off again when the alarm has stopped.
5.26.1Idle state
Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is to operate as an NC contact.
5.26.2Operating mode
Select an operating mode for the relay.
For example, if you want an
10 s.