20 en Installation

VideoJet X20

 

 

4.3Connections

4.3.1Cameras

You can connect two video sources to the VideoJet X20. Any cameras and other video sources that produce a standard PAL or NTSC signal are suitable.

1.Connect the cameras or other video sources to the BNC sockets Video In 1 and Video In 2 using a video cable (75 Ohm, BNC plug) .

2.If the video signal is not looped through, termination is performed by a software setting if necessary (see Section 5.13 Video Input, page 43).

4.3.2

Audio Connections

 

The VideoJet X20 has two audio ports for audio line signals.

 

The audio signals are transmitted two-way and in sync with the video signals. As a result, you

 

can connect a speaker or door intercom system at the destination point, for example. The

 

following specifications should be complied with in all cases.

 

 

 

 

 

2

× Line In:

Impedance 9 kOhm typ., 5.5 Vp-pmax. input voltage

 

1

× Line Out:

Impedance 10 kOhm typ., 3.0 Vp-pmax. output voltage,

 

 

 

impedance 16 Ohm min., 1.7 Vp-pmax. output voltage

The stereo plugs must be connected as follows:

Contact

Line In function

Line Out function

 

 

 

Tip

Channel 1 (camera 1)

Channel 1 (camera 1)

 

 

 

Middle ring

Channel 2 (camera 2)

 

 

 

Lower ring

Ground

Ground

 

 

 

1.Connect two audio sources with line level to the Audio In socket of the VideoJet X20 with a 3.5 mm stereo plug.

2.Connect a unit with line-in connection to the Audio Out socket of the VideoJet X20 with a 3.5 mm stereo plug.

4.3.3

 

Network

 

 

You can connect the VideoJet X20 to a 10/100 Base-T network using a standard UTP

 

 

category 5 cable with RJ45 plugs. The second Ethernet interface can be used to create a

 

 

redundant connection to the network.

 

 

 

 

i

NOTICE!

 

You cannot create a connection to a second network.

 

 

 

 

 

 

 

 

1.

Connect the VideoJet X20 to the network via the ETH 1 socket.

 

 

2.

Connect the VideoJet X20 to a redundant switch or hub on the same network via the

 

 

 

ETH 2 socket.

V3.5 2007.12