Connecting Electrical Loads |
|
| Stopping the Engine | ||||
1. Let engine stabilize and warm up for a few minutes | 1. | Turn OFF and unplug all electrical loads from generator | |||||
after starting. |
|
|
| panel receptacles. NEVER start or stop engine with | |||
2. Ensure circuit breaker on control panel is in on (I) |
|
| electrical devices plugged in and turned ON. | ||||
2. | Let engine run at | ||||||
position. |
| ||||||
3. Plug in and turn on the desired 120 and/or 240 Volt |
|
| stabilize internal temperatures of engine and generator. | ||||
3. | Turn key in start switch to off (O) position. | ||||||
AC, single phase, 60 Hz electrical loads. |
| ||||||
|
|
|
| ||||
NOTICE When plugging into the 120 Volt receptacles, plug |
|
| WARNING Fuel and its vapors are extremely flammable | ||||
items to be powered in sequence as shown below. |
|
| and explosive which could cause burns, | ||||
|
|
|
|
|
| fire or explosion resulting in death, | |
|
|
|
|
|
| ||
|
|
|
|
|
| serious injury and/or property damage. | |
|
|
|
|
| • DO NOT stop engine by moving choke control to choke ( ) | ||
|
|
|
|
| position. | ||
| 3 |
|
|
| |||
1 | 4. | Move fuel valve to “Off” position. |
|
|
|
|
| Low Oil Shutdown | |
|
| 2 |
|
| If the engine oil drops below a preset level, an oil switch will | |
|
| 4 |
| stop the engine. Check oil level with dipstick. | ||
|
|
|
| |||
|
|
|
|
| If oil level is between ADD and FULL mark on dipstick: | |
|
|
|
| 1. | DO NOT try to restart the engine. | |
|
|
| Reproduction | |||
|
|
|
| 2. | Contact an Authorized Briggs & Stratton Service Dealer. | |
NOTICE |
| 3. | DO NOT operate e gi e u til oil level is corrected. | |||
| • | DO NOT connect 240 Volt loads to the 120 Volt duplex |
| If il level is bel w ADD mark on dipstick: | ||
|
| receptacles. |
| 1. | Add oil o br ng level to FULL mark. | |
| • | DO NOT connect | 2. | Restart engine and if the engine stops again a low oil | ||
| • | DO NOT connect 50 Hz loads to the generat r. | for | ondition may still exist. DO NOT try to restart the | ||
| • DO NOT OVERLOAD THE GENERATOR. See D n’t |
|
| engine. | ||
|
| Overload Generator. |
| 3. | Contact an Authorized Briggs & Stratton Service Dealer. | |
NOTICE Exceeding generators wattage/amperage capacity | 4. | DO NOT operate engine until oil level is corrected. | ||||
could damage generator and/or electrical Notdevices connected |
|
|
| |||
to it. |
|
|
|
|
| |
• | DO NOT exceed the generator’s wattage/amperage ca acity. See |
|
|
| ||
| Don’t Overload Generator in the Operation section. |
|
|
| ||
• | Start generator and let engine stabilize before conn cting |
|
|
| ||
| electrical loads. |
|
|
|
|
• Connect electrical loads in OFF position, then turn ON for operation.
• Turn electrical loads OFF and disconnect from generator before stopping generator.
13