6)No paper fed manual feed slot

No paper in manual feeding

User Check

Load the paper

Step

Cause

Remedy

 

 

 

 

 

 

 

Harness connection failure of

Check the harness connection of the

1

registration front sensor PCB

registration front sensor PCB ASSY.

 

ASSY

 

 

 

 

 

Registration front sensor PCB

Check the registration front sensor

 

failure

performance following the procedure in

2

 

"Factory Inspection Mode" (Chapter 5).

 

 

If any problem occurs, replace the

 

 

registration front sensor PCB ASSY.

 

 

 

3

Toner sensor PCB failure

Replace the toner sensor PCB.

 

 

 

4

Main PCB failure

Replace the main PCB ASSY.

 

 

 

7)Drum error

Dirt on drum unit

User Check

Clean the corona wire in the drum unit.

Replace the drum unit with a new one, and reset the drum counter.

Step

Cause

Remedy

 

 

 

1

Dirt or dust on drum unit

Clean the electrodes on the drum unit

electrodes

(Refer to Fig. 1-1).

 

 

 

 

2

High-voltage power supply PCB

Replace the high-voltage power supply

failure

PCB.

 

 

 

 

3

Main PCB ASSY failure

Replace the main PCB ASSY failure.

 

 

 

1-10

Confidential