No paper in manual feeding
User Check
•Load the paper
Step | Cause | Remedy |
|
|
|
|
|
|
| Harness connection failure of | Check the harness connection of the |
1 | registration front sensor PCB | registration front sensor PCB ASSY. |
| ASSY |
|
|
|
|
| Registration front sensor PCB | Check the registration front sensor |
| failure | performance following the procedure in |
2 |
| "Factory Inspection Mode" (Chapter 5). |
|
| If any problem occurs, replace the |
|
| registration front sensor PCB ASSY. |
|
|
|
3 | Toner sensor PCB failure | Replace the toner sensor PCB. |
|
|
|
4 | Main PCB failure | Replace the main PCB ASSY. |
|
|
|
Dirt on drum unit
User Check
•Clean the corona wire in the drum unit.
•Replace the drum unit with a new one, and reset the drum counter.
Step | Cause | Remedy | |
|
|
| |
1 | Dirt or dust on drum unit | Clean the electrodes on the drum unit | |
electrodes | |||
| |||
|
|
| |
2 | Replace the | ||
failure | PCB. | ||
| |||
|
|
| |
3 | Main PCB ASSY failure | Replace the main PCB ASSY failure. | |
|
|
|
Confidential |