Poor fixing

User Check

• Replace the drum unit with a new one.

• Replace the toner cartridge with a new one.

Step

Cause

Check

Result

Remedy

 

 

 

 

 

 

 

 

 

 

 

Fuser unit failure

Is the problem solved

 

Replace the fuser unit.

1

 

after replacing the fuser

Yes

 

 

 

unit?

 

 

 

 

 

 

 

 

Low-voltage

Is the problem solved

 

Replace the PS PCB unit.

2

power supply

after replacing the PS

Yes

 

 

PCB failure

PCB unit?

 

 

 

 

 

 

 

 

HVPS PCB

Is the problem solved

 

Replace the HVPS PCB

3

failure

after replacing the

Yes

ASSY.

 

 

HVPS PCB ASSY?

 

 

 

 

 

 

 

 

Main PCB failure

Is the problem solved

 

Replace the main PCB

4

 

after replacing the main

Yes

ASSY.

 

 

PCB ASSY?

 

 

 

 

 

 

 

Completely blank

User Check

Replace the drum unit with a new one.

Replace the toner cartridge with a new one.

Step

Cause

Check

Result

Remedy

 

 

 

 

 

 

 

 

 

 

 

Developing bias

Are the electrodes on

 

Clean both electrodes.

1

voltage

the drum unit and

Yes

 

conduction

machine body dirty?

 

 

 

 

 

failure

 

 

 

 

 

 

 

 

 

Scanner harness

Is the scanner harness

 

Reconnect the scanner

2

of the laser unit

of the laser unit

No

harness of the laser unit.

connection

connected securely?

 

 

 

 

 

failure

 

 

 

 

 

 

 

 

 

Laser unit failure

Is the problem solved

 

Replace the laser unit.

3

 

after replacing the laser

Yes

 

 

 

unit?

 

 

 

 

 

 

 

 

HVPS PCB

Is the problem solved

 

Replace the HVPS PCB

4

failure

after replacing the

Yes

ASSY.

 

 

HVPS PCB ASSY?

 

 

 

 

 

 

 

 

Main PCB failure

Is the problem solved

 

Replace the main PCB

5

 

after replacing the main

Yes

ASSY.

 

 

PCB ASSY?

 

 

 

 

 

 

 